Starting from the experience of the staff who maintain the wind power tower shot blasting machine, the maintenance of the mechanical actuator of the wind power tower shot blasting machine should take different key maintenance measures according to different periods of use, we usually have to do the following:
Product Details
Starting from the experience of the staff who maintain the wind power tower shot blasting machine, the maintenance of the mechanical actuator of the wind power tower shot blasting machine should take different key maintenance measures according to different periods of use, we usually have to do the following:

(1) Regular lubrication: the motor and transmission components of the wind power tower shot blasting mechanical actuator need to use lubricating oil to lubrize, and the viscosity of the lubricating oil changes with the oil temperature. The viscosity of lubricating oil is too low, and the damage degree of gear and other parts increases; On the contrary, the viscosity is too high, which will lead to poor action. All lubricating oil should be added regularly to extend its service life.

(2) Improve the operating environment: In order to ensure the reliability of the dynamic actuator of the wind power tower shot blasting machine, it must be ensured that it can operate in a normal operating environment to avoid short circuit or other faults caused by environmental factors such as humidity.

(3) Regular inspection: Regular inspection and timely discovery of hidden dangers in the process of the accident, for the search of fault factors can be helpful to avoid the wrong way in the maintenance.

(4) Make the management of the fault account: every fault handled should be recorded in detail, including the fault phenomenon, the cause of the fault in the analysis and search process, the treatment method and the preventive measures. This is not only to provide reference value for dealing with similar problems in the future, but also to improve the technical level of finding fault factors, and play a multiplier effect.